Choose the wrong material for a sulfuric acid pump and the consequences range from accelerated corrosion, shortened seal life, and rising repair bills to a pump-body leak—putting you up against one of the most dangerous chemicals in industry. At Teffiko, we select chemical centrifugal pumps for sulfuric acid service every day. This article compares the sulfuric acid pump materials actually used in engineering, explains the service window and failure mechanism of each, and gives a material-selection framework you can apply directly.
Sulfuric acid is the most-produced industrial chemical in the world, with an annual
output of over 200 million tons; it is widely used in fertilizers, storage batteries,
mining and metallurgy, petroleum refining, and chemical synthesis.
Its corrosion mechanism changes completely with concentration:
Therefore, selection must cover all conditions the pump may encounter—start-up, shut-down, flushing, and process fluctuations—not just the rated design point.
For 80–98% sulfuric acid at ambient temperature, gray cast iron (HT200/HT250) and WCB carbon steel are the standard, most economical choice: the protective layer forms from the acid itself, so no expensive alloy is needed.
The passivation film exists only in strong acid. Below 80% it dissolves; 65–80% is the most dangerous range for iron, where cast iron and carbon steel must never be used. Excessive temperature, high velocity or bubble impingement that damages the film, and water entering the pump and diluting the acid can all break it down. Cast iron must never be used for oleum: free sulfur trioxide reacts with the silicon in cast iron and causes brittle cracking.
Conclusion: for tightly controlled concentrated-acid tank transfer, this is economical and reliable, but it has almost no margin for concentration or temperature fluctuation.
316L is the default “chemical-grade” stainless steel—and also the most misused material in sulfuric acid pumps. Its chromium-oxide passivation layer is dissolved by dilute and medium-concentration sulfuric acid, because it lacks the copper and high nickel content needed to resist reducing acids.
316L is acceptable only in an extremely narrow window: 93–100% at ambient temperature, and extremely dilute acid below 5%; it fails rapidly across the 10–90% range.
Conclusion: do not treat 316L as the default material for sulfuric acid pumps; it saves on paper but costs dearly in the field.
Alloy 20 is a nickel-iron-chromium alloy deliberately alloyed with 3–4% copper and 2–3% molybdenum specifically to combat sulfuric acid corrosion. Typical composition: Ni 32–38%, Cr 19–21%, Mo 2–3%, Cu 3–4%, balance iron.
Above 60–66°C in medium concentrations, corrosion accelerates sharply; high temperature, impurities, or strongly oxidizing fluids exceed its capability. It costs about 3–4 times as much as 316L, but far less than specialty alloys.
Best for: battery acid transfer and circulation, fertilizer acid systems, medium-temperature chemical feed, metal-surface pickling, and acid-cleaning loops.
C-276 is a nickel-molybdenum-chromium superalloy (Ni ~57%, Mo 15–17%, Cr 14.5–16.5%, W 3–4.5%) and one of the most corrosion-resistant metal alloys in industry.
The only bottleneck is price: about 5–8 times 316L and 1.5–2.5 times Alloy 20. Where Alloy 20 already suffices, the premium buys no proportional service life.
Best for: hot acid above 60°C, high-temperature concentrated acid, chloride-bearing mixed acids, oleum, high-velocity circulation, and critical production lines where downtime cost far exceeds the alloy premium.
PVDF is a semi-crystalline fluoropolymer in the same family as PTFE, but it can be injection-molded and machined into pump casings and impellers; its carbon-fluorine backbone provides chemical shielding.
Limitations: low mechanical strength, creep under long-term load, brittle fracture on impact, and attack by certain organic solvents.
When you need fluoropolymer corrosion resistance but cannot accept the pressure limits of an all-plastic pump, a steel casing lined with PTFE or FEP (F46) covers nearly all concentrations and withstands about 80°C.
Two cautions: high temperature and thermal shock cause blistering and delamination of the liner; water ingress locally dilutes the acid, releases heat, and damages the liner. Also, concentrated sulfuric acid has a specific gravity of about 1.84; the motor must be sized for SG 1.84 rather than water, or it will overload.
| Property | Cast Iron / Carbon Steel | 316L | Alloy 20 | C-276 | PVDF | PTFE/FEP Lined |
|---|---|---|---|---|---|---|
| Optimal Concentration | 80–98% | Only >93% or <5% | 5–98% (best at 10–70%) | All ranges, including fuming acid | ≤70% | Almost all concentrations |
| Max Temperature | 50–60°C | Ambient only | ~66°C | ~120°C | ~120°C (low pressure) | ~80°C |
| Dilute / Medium Concentration | Not suitable | Not suitable | Excellent | Excellent | Excellent | Excellent |
| Concentrated Sulfuric Acid 93–98% | Good (low temp) | Good (ambient) | Good | Excellent | Not applicable | Excellent |
| Chloride Resistance | Poor | Poor | Moderate | Excellent | Excellent | Excellent |
| Metal Ion Leaching | Yes | Yes | Yes | Yes | No | No |
| Relative Cost | Lowest | Low | Medium-high | Very high | Medium | Medium-high |
| Best Suited For | Controlled 98% tank transfer | — | Battery / industrial acid | High temp / contaminated / critical service | High purity, ≤70% | Wide service range, pressurized |
1. What is the full concentration range (including the worst case)? If the acid stays below 70% and purity is required, choose PVDF; between 70–98%, choose between Alloy 20 and C-276; for tightly controlled 80–98% ambient-temperature transfer, cast iron/carbon steel remains economical.
2. What is the highest possible temperature? Below 60°C, Alloy 20 covers most conditions; above 60–70°C, or where temperature fluctuations occur, choose C-276.
3. Are chlorides or mixed impurities present? For chloride-bearing service, choose C-276 or a non-metallic solution; Alloy 20's chloride resistance is only moderate. If metal-ion contamination of the product is absolutely unacceptable, only PVDF or a fluoropolymer-lined construction will do.
1. Using 316L as the default “chemical-grade” material in the intermediate-concentration range.
2. Exposing cast iron to fluctuating service where concentration may drop below 80%.
3. Selecting material by rated temperature rather than the maximum credible temperature.
4. Ignoring velocity: keep suction below 1.5 m/s and discharge below 3 m/s; high velocity strips off the passivation film.
5. Sizing the motor for water instead of SG 1.84 concentrated acid.
What is the best material for a sulfuric acid pump? There is no single answer. For battery and industrial acid below 60°C, Alloy 20 is the most practical; for high temperature, high concentration, contamination, or critical lines, choose C-276; for controlled 80–98% ambient transfer, use cast iron/carbon steel; for high purity or dilute service, choose PVDF or a lined pump.
Can cast iron handle 70% sulfuric acid? No. Below 80% the passivation film dissolves, and 65–80% is most dangerous for iron; switch to a fluoropolymer-lined pump or Alloy 20.
Is C-276 always better than Alloy 20? It resists a wider range, but costs 1.5–2.5 times more. For stable, medium-temperature battery or process acid, Alloy 20 provides adequate life at far lower cost.
Can a lined pump handle 98% sulfuric acid? Chemically, yes. The limits are thermal shock, water ingress, the 80°C temperature ceiling that protects the liner bond, plus a motor sized for SG 1.84.
The best material for a sulfuric acid pump is the one matched to the full concentration and temperature envelope of the acid: cast iron handles controlled concentrated-acid transfer, Alloy 20 handles everyday industrial and battery acid, C-276 handles high temperature and severe service, and PVDF or a lined solution handles purity and broad chemical tolerance.
If your service falls between two materials, or you need to confirm the concentration range, temperature margin, and seal configuration, Teffiko's engineering team can give you a clear wetted-parts, seal, and motor-power package based on your actual operating data. Send Teffiko the concentration, temperature, flow rate, and head, and get a pump proposal with the material confirmed—not a generic catalog quote.